Results 1 - 20 de 31
Filter
1.
Journal of Breast Cancer ; : 353-362, 2023.
Article in English | WPRIM | ID: wpr-1000776

ABSTRACT

Purpose@#Several predictive models have been developed to predict the pathological complete response (pCR) after neoadjuvant chemotherapy (NAC); however, few are broadly applicable owing to radiologic complexity and institution-specific clinical variables, and none have been externally validated. This study aimed to develop and externally validate a machine learning model that predicts pCR after NAC in patients with breast cancer using routinely collected clinical and demographic variables. @*Methods@#The electronic medical records of patients with advanced breast cancer who underwent NAC before surgical resection between January 2017 and December 2020 were reviewed. Patient data from Seoul National University Bundang Hospital were divided into training and internal validation cohorts. Five machine learning techniques, including gradient boosting machine (GBM), support vector machine, random forest, decision tree, and neural network, were used to build predictive models, and the area under the receiver operating characteristic curve (AUC) was compared to select the best model. Finally, the model was validated using an independent cohort from Seoul National University Hospital. @*Results@#A total of 1,003 patients were included in the study: 287, 71, and 645 in the training, internal validation, and external validation cohorts, respectively. Overall, 36.3% of the patients achieved pCR. Among the five machine learning models, the GBM showed the highest AUC for pCR prediction (AUC, 0.903; 95% confidence interval [CI], 0.833–0.972).External validation confirmed an AUC of 0.833 (95% CI, 0.800–0.865). @*Conclusion@#Commonly available clinical and demographic variables were used to develop a machine learning model for predicting pCR following NAC. External validation of the model demonstrated good discrimination power, indicating that routinely collected variables were sufficient to build a good prediction model.

2.
Korean Journal of Radiology ; : 866-877, 2022.
Article in English | WPRIM | ID: wpr-938777

ABSTRACT

Objective@#The optimal imaging approach for evaluating pathological nipple discharge remains unclear. We investigated the value of adding ductography to ultrasound (US) for evaluating pathologic nipple discharge in patients with negative mammography findings. @*Materials and Methods@#From July 2003 to December 2018, 101 women (mean age, 46.3 ± 12.2 years; range, 23–75 years) with pathologic nipple discharge were evaluated using pre-ductography (initial) US, ductography, and post-ductography US. The imaging findings were reviewed retrospectively. The standard reference was surgery (70 patients) or > 2 years of followup with US (31 patients). The diagnostic performances of initial US, ductography, and post-ductography US for detecting malignancy were compared using the McNemar’s test or a generalized estimating equation. @*Results@#In total, 47 papillomas, 30 other benign lesions, seven high-risk lesions, and 17 malignant lesions were identified as underlying causes of pathologic nipple discharge. Only eight of the 17 malignancies were detected on the initial US, while the remaining nine malignancies were detected by ductography. Among the nine malignancies detected by ductography, eight were detected on post-ductography US and could be localized for US-guided intervention. The sensitivities of ductography (94.1% [16/17]) and post-ductography US (94.1% [16/17]) were significantly higher than those of initial US (47.1% [8/17]; p = 0.027 and 0.013, respectively). The negative predictive value of post-ductography US (96.9% [31/32]) was significantly higher than that of the initial US (83.3% [45/54]; p = 0.006). Specificity was significantly higher for initial US than for ductography and post-ductography US (p = 0.001 for all). @*Conclusion@#The combined use of ductography and US has a high sensitivity for detecting malignancy in patients with pathologic nipple discharge and negative mammography. Ductography findings enable lesion localization on second-look post-ductography US, thus facilitating the selection of optimal treatment plans.

3.
Ultrasonography ; : 520-529, 2021.
Article in English | WPRIM | ID: wpr-919545

ABSTRACT

Purpose@#This study aimed to predict a heavy nodal burden (≥3 metastatic axillary lymph nodes [LNs]) using axillary ultrasonography (US) and US-guided fine-needle aspiration biopsy (FNAB) in patients with early-stage breast cancer. @*Methods@#We retrospectively reviewed the medical records of 403 women (404 cancers) who underwent US-guided FNAB for axillary LN staging from January 2006 to December 2015. US findings and US-guided FNAB results were reviewed and compared using pathology results as the reference. Diagnostic performance was analyzed, and clinicopathological and radiological findings were compared between patients with <3 metastatic LNs and ≥3 metastatic LNs. @*Results@#The final pathology results revealed that 20.5% of cancers had heavy nodal metastases. US-guided FNAB showed significantly higher sensitivity (79.0% vs. 63.0%, P=0.009) and specificity (84.8% vs. 79.3%, P=0.036) in predicting heavy nodal metastases than did US. The presence of a larger number of suspicious LNs (two or more) on axillary US and positive FNAB results were significantly correlated with a heavy nodal burden in the multivariate analysis. The odds ratios were 4.20 (95% confidence interval [CI], 1.90 to 9.39) for two suspicious LNs, 9.40 (95% CI, 2.99 to 29.54) for three or more suspicious LNs, and 14.22 (95% CI, 6.78 to 29.82) for positive FNAB results. @*Conclusion@#The number of suspicious LNs detected on axillary US and FNAB results can help predict a heavy axillary nodal burden in patients with early-stage breast cancer.

4.
Ultrasonography ; : 83-92, 2021.
Article in English | WPRIM | ID: wpr-919514

ABSTRACT

Purpose@#The purpose of this study was to measure the cancer detection rate of computer-aided detection (CAD) software in preoperative automated breast ultrasonography (ABUS) of breast cancer patients and to determine the characteristics associated with false-negative outcomes. @*Methods@#A total of 129 index lesions (median size, 1.7 cm; interquartile range, 1.2 to 2.4 cm) from 129 consecutive patients (mean age±standard deviation, 53.4±11.8 years) who underwent preoperative ABUS from December 2017 to February 2018 were assessed. An index lesion was defined as a breast cancer confirmed by ultrasonography (US)-guided core needle biopsy. The detection rate of the index lesions, positive predictive value (PPV), and false-positive rate (FPR) of the CAD software were measured. Subgroup analysis was performed to identify clinical and US findings associated with false-negative outcomes. @*Results@#The detection rate of the CAD software was 0.84 (109 of 129; 95% confidence interval, 0.77 to 0.90). The PPV and FPR were 0.41 (221 of 544; 95% CI, 0.36 to 0.45) and 0.45 (174 of 387; 95% CI, 0.40 to 0.50), respectively. False-negative outcomes were more frequent in asymptomatic patients (P<0.001) and were associated with the following US findings: smaller size (P=0.001), depth in the posterior third (P=0.002), angular or indistinct margin (P<0.001), and absence of architectural distortion (P<0.001). @*Conclusion@#The CAD software showed a promising detection rate of breast cancer. However, radiologists should judge whether CAD software-marked lesions are true- or false-positive lesions, considering its low PPV and high FPR. Moreover, it would be helpful for radiologists to consider the characteristics associated with false-negative outcomes when reading ABUS with CAD.

5.
Korean Journal of Radiology ; : 431-441, 2020.
Article in English | WPRIM | ID: wpr-811000

ABSTRACT

OBJECTIVE: To compare the diagnostic performance and interobserver variability of strain ratio obtained from one or two regions of interest (ROI) on breast elastography.MATERIALS AND METHODS: From April to May 2016, 140 breast masses in 140 patients who underwent conventional ultrasonography (US) with strain elastography followed by US-guided biopsy were evaluated. Three experienced breast radiologists reviewed recorded US and elastography images, measured strain ratios, and categorized them according to the American College of Radiology breast imaging reporting and data system lexicon. Strain ratio was obtained using the 1-ROI method (one ROI drawn on the target mass), and the 2-ROI method (one ROI in the target mass and another in reference fat tissue). The diagnostic performance of the three radiologists among datasets and optimal cut-off values for strain ratios were evaluated. Interobserver variability of strain ratio for each ROI method was assessed using intraclass correlation coefficient values, Bland–Altman plots, and coefficients of variation.RESULTS: Compared to US alone, US combined with the strain ratio measured using either ROI method significantly improved specificity, positive predictive value, accuracy, and area under the receiver operating characteristic curve (AUC) (all p values < 0.05). Strain ratio obtained using the 1-ROI method showed higher interobserver agreement between the three radiologists without a significant difference in AUC for differentiating breast cancer when the optimal strain ratio cut-off value was used, compared with the 2-ROI method (AUC: 0.788 vs. 0.783, 0.693 vs. 0.715, and 0.691 vs. 0.686, respectively, all p values > 0.05).CONCLUSION: Strain ratios obtained using the 1-ROI method showed higher interobserver agreement without a significant difference in AUC, compared to those obtained using the 2-ROI method. Considering that the 1-ROI method can reduce performers' efforts, it could have an important role in improving the diagnostic performance of breast US by enabling consistent management of breast lesions.

6.
Journal of the Korean Radiological Society ; : 919-929, 2019.
Article in English | WPRIM | ID: wpr-916839

ABSTRACT

PURPOSE@#This study aimed to analyze the current practices of breast imaging among Korean radiologists.@*MATERIALS AND METHODS@#We invited members of the Korean Society of Breast Imaging (KSBI) working as breast radiologists to participate in a survey on the current practices in breast imaging, and investigated how quality assurance (QA), medical audits, and imaging-histologic discordance were conducted.@*RESULTS@#The survey involved 312 members of the KSBI, and 116 (37%) responded to the 21 questions in the questionnaire. Most of the respondents were women (87%), aged below 50 years (82.7%), and working at university or tertiary hospitals (68.1%), who had varying levels of experience in breast imaging. Of the 116 respondents, 114 (96.6%) followed the Breast Imaging Reporting and Data System (BI-RADS) to interpret breast imaging. Out of 116, 72 (62.1%) interpreted 20 or more mammograms per day, 84 (72.4%) performed 10–30 breast ultrasound scans per day, and 65 (56%) interpreted fewer than 5 breast MRI scans per day. Among the respondents, 82% performed mammography QA, 76.9% evaluated imaging-histologic correlations, and only 38.9% performed medical audits.@*CONCLUSION@#The institutions and working patterns of breast radiologists were diverse. Although many respondents did not conduct medical audits, most of them followed BI-RADS when interpreting breast imaging, performing QA, and evaluating imaging-histologic correlations.

7.
Journal of the Korean Radiological Society ; : 32-46, 2019.
Article in Korean | WPRIM | ID: wpr-916732

ABSTRACT

Automated breast ultrasonography (ABUS) is a recently introduced technology. Similar to handheld ultrasound (HHUS), it is a supplementary screening test for breast cancer to be used along with mammography. It is particularly useful for detecting invasive breast cancers that may be overlooked by mammography in denser breast tissue. The use of ABUS is becoming more common because of the advantages of low operator dependency during image acquisition, high reproducibility, a wide field-of-view, and unavailability of better coronal imaging with HHUS. Consequently, there have been suggestions to extend ABUS use to diagnostic screening. Therefore, in this paper, we provide a review of the literature and discuss the usefulness and value of ABUS in breast cancer screening.

8.
Journal of Nutrition and Health ; : 559-568, 2019.
Article in Korean | WPRIM | ID: wpr-786114

ABSTRACT

PURPOSE: This study examined the prevalence of food allergies and allergenic factors in a selected sample of children living in Seoul, Korea, along with their dietary habits, environmental factors, and diseases as risk factors for food allergy. The results of this study will provide basic data for addressing food allergies.METHODS: We selected 3,004 pre-school and school-age children, aged 0 ~ 12, in the 25 districts of Seoul as the study sample. Structured self-report questionnaires were administered over a two-month period in July-August 2018, and the children's parents recorded the answers on their children's behalf. The research tools in this study included the Korean version of the questionnaire from the International Study of Asthma and Allergies in Childhood (ISAAC).RESULTS: The physician-diagnosed prevalence rate of food allergies was 14.2%, while 20.4% of the children experienced allergic symptoms at least once and 17.4% reported symptoms within the previous 12 months. The children's symptoms included skin problems (88.1%), gastrointestinal issues (19.2%), oral issues (16.7%), respiratory issues (12.7%), and systemic issues (1.3%). The causes of allergies included eggs, peaches, milk, peanuts, and shrimps. The factors influencing the experience of food allergies were the consumption of cereal (aOR, 1.52; 95% CI, 1.09 ~ 2.10; p = 0.013), potatoes (aOR, 1.88; 95% CI, 1.33 ~ 2.65; p < 0.001), and fast food (aOR, 1.73; 95% CI, 1.10 ~ 2.72; p = 0.017). Having food allergy symptoms was associated with a higher risk of experiencing asthma (aOR, 4.22 95% CI, 3.10 ~ 5.76; p < 0.001), allergic rhinitis (aOR, 2.53; 95% CI, 2.03 ~ 3.15; p < 0.001), and atopic dermatitis symptoms (aOR, 3.56; 95% CI, 2.88 ~ 4.40; p < 0.001).CONCLUSION: Episodes of food allergies warrant examining regular food consumption and placing dietary restrictions through early diagnosis as these episodes may imply the presence of other allergies. Our findings offer basic insights into the patterns, prevalence and symptoms of children's food allergies in Seoul, and our findings will contribute to identifying effective interventions for food allergies.


Subject(s)
Child , Humans , Arachis , Asthma , Dermatitis, Atopic , Early Diagnosis , Edible Grain , Eggs , Fast Foods , Feeding Behavior , Food Hypersensitivity , Hypersensitivity , Korea , Milk , Ovum , Parents , Prevalence , Prunus persica , Rhinitis, Allergic , Risk Factors , Seoul , Skin , Solanum tuberosum
9.
Ultrasonography ; : 264-271, 2019.
Article in English | WPRIM | ID: wpr-761979

ABSTRACT

PURPOSE: The purpose of this study was to assess the reliability of automated breast ultrasound (ABUS) examinations of suspicious breast masses in comparison to handheld breast ultrasound (HHUS) with regard to Breast Imaging Reporting and Data System (BI-RADS) category assessment, and to investigate the factors affecting discrepancies in categorization. METHODS: A total of 135 masses that were assessed as BI-RADS categories 4 and 5 on ABUS that underwent ultrasound (US)-guided core needle biopsy from May 2017 to December 2017 were included in this study. The BI-RADS categories were re-assessed using HHUS. Agreement of the BI-RADS categories was evaluated using kappa statistics, and the positive predictive value of each examination was calculated. Logistic regression analysis was performed to identify the mammography and US findings associated with discrepancies in the BI-RADS categorization. RESULTS: The overall agreement between ABUS and HHUS in all cases was good (79.3%, kappa=0.61, P<0.001). Logistic regression analysis revealed that accompanying suspicious microcalcifications on mammography (odds ratio [OR], 4.63; 95% confidence interval [CI], 1.83 to 11.71; P=0.001) and an irregular shape on US (OR, 5.59; 95% CI, 1.43 to 21.83; P=0.013) were associated with discrepancies in the BI-RADS categorization. CONCLUSION: The agreement between ABUS and HHUS examinations in the BI-RADS categorization of suspicious breast masses was good. The presence of suspicious microcalcifications on mammography and an irregular shape on US were factors associated with ABUS yielding a lower level of suspicion than HHUS in terms of the BI-RADS category assessment.


Subject(s)
Biopsy, Large-Core Needle , Breast Neoplasms , Breast , Information Systems , Logistic Models , Mammography , Ultrasonography
10.
Journal of Breast Cancer ; : 80-86, 2018.
Article in English | WPRIM | ID: wpr-713694

ABSTRACT

PURPOSE: The management of benign intraductal papilloma (IDP) without atypia diagnosed on core needle biopsy (CNB) remains controversial. This study was performed to evaluate the rate of upgrading to malignancy or high-risk lesions after excision and to identify factors associated with upgrading using a large series of benign IDP cases without atypia. METHODS: We included patients who were diagnosed as having benign IDP without atypia on CNB and underwent surgical or vacuum-assisted excision between 2010 and 2015. We analyzed the clinical, radiologic, and histopathologic features of IDPs that were upgraded to malignancy or high-risk lesions after excision. RESULTS: A total of 511 benign IDPs without atypia diagnosed via CNB were identified, of which 398 cases were treated with excision. After reviewing these cases, four cases of high-risk lesions in adjacent tissue on CNB, two cases which were revealed as papilloma with atypia, and nine cases of malignancy in the same breast were excluded. In the remaining 383 cases, the rate of upgrading to malignancy and high-risk lesions after excision was 0.8% and 4.4%, respectively. The presence of concurrent contralateral breast cancer, the presence of symptoms, and multifocality were factors significantly associated with upgrading to malignancy on subsequent excision. Surgical excision rather than vacuum-assisted excision was significantly associated with upgrading to high-risk lesions or malignancy. CONCLUSION: The rate of upgrading to malignancy for benign IDP without atypia was very low, suggesting that close clinical and radiologic observation may be sufficient for patients with benign IDP without atypia on CNB under proper settings.


Subject(s)
Humans , Biopsy, Large-Core Needle , Breast , Breast Neoplasms , Papilloma , Papilloma, Intraductal
11.
Investigative Magnetic Resonance Imaging ; : 233-241, 2017.
Article in English | WPRIM | ID: wpr-119937

ABSTRACT

PURPOSE: To report on the current practices in breast magnetic resonance imaging (MRI) in Korea. MATERIALS AND METHODS: We invited the 68 members of the Korean Society of Breast Imaging who were working in hospitals with available breast MRI to participate in a survey on how they performed and interpreted breast MRI. We asked one member from each hospital to respond to the survey. A total of 22 surveys from 22 hospitals were analyzed. RESULTS: Out of 22 hospitals, 13 (59.1%) performed at least 300 breast MRI examinations per year, and 5 out of 22 (22.7%) performed > 1200 per year. Out of 31 machines, 14 (45.2%) machines were 1.5-T scanners and 17 (54.8%) were 3.0-T scanners. All hospitals did contrast-enhanced breast MRI. Full-time breast radiologists supervised the performance and interpreted breast MRI in 19 of 22 (86.4%) of hospitals. All hospitals used BI-RADS for MRI interpretation. For computer-aided detection (CAD), 13 (59.1%) hospitals sometimes or always use it and 9 (40.9%) hospitals did not use CAD. Two (9.1%) and twelve (54.5%) hospitals never and rarely interpreted breast MRI without correlating the mammography or ultrasound, respectively. The majority of respondents rarely (13/21, 61.9%) or never (5/21, 23.8%) interpreted breast MRI performed at an outside facility. Of the hospitals performing contrast-enhanced examinations, 15 of 22 (68.2%) did not perform MRI-guided interventional procedures. CONCLUSION: Breast MRI is extensively performed in Korea. The indication and practical patterns are diverse. The information from this survey would provide the basis for the development of Korean breast MRI practice guidelines.


Subject(s)
Breast Neoplasms , Breast , Diagnosis , Korea , Magnetic Resonance Imaging , Mammography , Surveys and Questionnaires , Ultrasonography
12.
Journal of Korean Medical Science ; : 1689-1697, 2015.
Article in English | WPRIM | ID: wpr-198118

ABSTRACT

This study aimed to evaluate the reproducibility of apparent diffusion coefficient (ADC) measurements in malignant breast masses, and to determine the influence of mammographic parenchymal density on this reproducibility. Sixty-six patients with magnetic resonance findings of the mass were included. Two breast radiologists measured the ADC of the malignant breast mass and the same area on the contralateral normal breast in each patient twice. The effects of mammographic parenchymal density, histology, and lesion size on reproducibility were also assessed. There was no significant difference in the mean ADC between repeated measurements in malignant breast masses and normal breast tissue. The overall reproducibility of ADC measurements was good in both. The 95% limits of agreement for repeated ADCs were approximately 30.2%-33.4% of the mean. ADC measurements in malignant breast masses were highly reproducible irrespective of mass size, histologic subtype, or coexistence of microcalcifications; however, the measurements tended to be less reproducible in malignant breast masses with extremely dense parenchymal backgrounds. ADC measurements in malignant breast masses are highly reproducible; however, mammographic parenchymal density can potentially influence this reproducibility.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Middle Aged , Algorithms , Breast Neoplasms/pathology , Diffusion Magnetic Resonance Imaging/methods , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Reproducibility of Results , Sensitivity and Specificity
13.
Korean Journal of Radiology ; : 305-312, 2014.
Article in English | WPRIM | ID: wpr-203190

ABSTRACT

OBJECTIVE: To compare new full-field digital mammography (FFDM) with and without use of an advanced post-processing algorithm to improve image quality, lesion detection, diagnostic performance, and priority rank. MATERIALS AND METHODS: During a 22-month period, we prospectively enrolled 100 cases of specimen FFDM mammography (Brestige(R)), which was performed alone or in combination with a post-processing algorithm developed by the manufacturer: group A (SMA), specimen mammography without application of "Mammogram enhancement ver. 2.0"; group B (SMB), specimen mammography with application of "Mammogram enhancement ver. 2.0". Two sets of specimen mammographies were randomly reviewed by five experienced radiologists. Image quality, lesion detection, diagnostic performance, and priority rank with regard to image preference were evaluated. RESULTS: Three aspects of image quality (overall quality, contrast, and noise) of the SMB were significantly superior to those of SMA (p < 0.05). SMB was significantly superior to SMA for visualizing calcifications (p < 0.05). Diagnostic performance, as evaluated by cancer score, was similar between SMA and SMB. SMB was preferred to SMA by four of the five reviewers. CONCLUSION: The post-processing algorithm may improve image quality with better image preference in FFDM than without use of the software.


Subject(s)
Adult , Aged , Female , Humans , Middle Aged , Algorithms , Breast Neoplasms/diagnostic imaging , Calcinosis/diagnostic imaging , Mammography/methods , Prospective Studies , Radiographic Image Enhancement/methods , Sensitivity and Specificity , Software
14.
Journal of the Korean Society of Magnetic Resonance in Medicine ; : 133-143, 2014.
Article in English | WPRIM | ID: wpr-152826

ABSTRACT

PURPOSE: The aim of this study was to determine the magnetic resonance imaging (MRI) features associated with re-excision due to the presence of a positive margin after breast conserving therapy (BCT) in breast cancer patients. MATERIALS AND METHODS: We reviewed the records of 286 consecutive breast cancer patients who received BCT between January 2006 and December 2007. Among 246 patients who had undergone BCT, 38 (15.4%) underwent immediate further surgery due to positive margin status. We analyzed the MRI findings using chi2 test, Fisher's exact test and t tests. Multivariate logistic regression was conducted for prediction of re-excision. RESULTS: Tumor size (p or = 5 cm) (odds ratio = 2.96), NMLE (odds ratio = 3.81), and multifocal lesions (odds ratio = 2.54) were positively associated with re-excision. In cases involving NMLE, segmental distribution was associated with a greater likelihood of immediate re-excision. CONCLUSION: Larger size, multiplicity, and NMLE on MRI are significantly associated with re-excision after BCT in breast cancer patients. For NMLE lesions, the segmental distribution pattern was predictive of re-excision.


Subject(s)
Humans , Breast , Breast Neoplasms , Logistic Models , Magnetic Resonance Imaging
15.
Korean Journal of Radiology ; : 411-422, 2014.
Article in English | WPRIM | ID: wpr-109972

ABSTRACT

OBJECTIVE: To synthesize mesoporous silica-core-shell magnetic nanoparticles (MNPs) encapsulated by liposomes (Lipo [MNP@m-SiO2]) in order to enhance their stability, allow them to be used in any buffer solution, and to produce trastuzumab-conjugated (Lipo[MNP@m-SiO2]-Her2Ab) nanoparticles to be utilized in vitro for the targeting of breast cancer. MATERIALS AND METHODS: The physiochemical characteristics of Lipo[MNP@m-SiO2] were assessed in terms of size, morphological features, and in vitro safety. The multimodal imaging properties of the organic dye incorporated into Lipo[MNP@m-SiO2] were assessed with both in vitro fluorescence and MR imaging. The specific targeting ability of trastuzumab (Her2/neu antibody, Herceptin(R))-conjugated Lipo[MNP@m-SiO2] for Her2/neu-positive breast cancer cells was also evaluated with fluorescence and MR imaging. RESULTS: We obtained uniformly-sized and evenly distributed Lipo[MNP@m-SiO2] that demonstrated biological stability, while not disrupting cell viability. Her2/neu-positive breast cancer cell targeting by trastuzumab-conjugated Lipo[MNP@m-SiO2] was observed by in vitro fluorescence and MR imaging. CONCLUSION: Trastuzumab-conjugated Lipo[MNP@m-SiO2] is a potential treatment tool for targeted drug delivery in Her2/neu-positive breast cancer.


Subject(s)
Animals , Female , Humans , Mice , 3T3 Cells , Antibodies, Monoclonal, Humanized/administration & dosage , Antineoplastic Agents/administration & dosage , Breast Neoplasms/chemistry , Cell Line, Tumor , Drug Delivery Systems/methods , Ferric Compounds/chemistry , Liposomes , Magnetite Nanoparticles/administration & dosage , Molecular Targeted Therapy/methods , Nanoconjugates/administration & dosage , Nanoparticles/chemistry , Receptor, ErbB-2/immunology , Silicon Dioxide/administration & dosage
16.
Journal of the Korean Society of Medical Ultrasound ; : 207-211, 2013.
Article in English | WPRIM | ID: wpr-725526

ABSTRACT

Plasmacytoma of the breast is a rare tumorous condition referring to an extramedullary proliferation of malignant plasma cells, commonly associated with multiple myeloma. Due to its rarity, little is known about the radiologic findings to date. We report on a case of plasmacytoma of the breast as a manifestation of multiple myeloma with its radiopathologic correlation.


Subject(s)
Breast , Multiple Myeloma , Plasma Cells , Plasmacytoma
17.
Korean Journal of Radiology ; : 164-170, 2013.
Article in English | WPRIM | ID: wpr-15373

ABSTRACT

OBJECTIVE: To compare the diagnostic performance of new and established full-field digital mammography (FFDM) systems. MATERIALS AND METHODS: During a 15-month period, 1038 asymptomatic women who visited for mammography were prospectively included from two institutions. For women with routine two-view mammograms from established FFDM systems, bilateral mediolateral oblique (MLO) mammograms were repeated using the new FFDM system. One of the four reviewers evaluated two-sets of bilateral MLO mammograms at 4-week intervals by using a five-point score for the probability of malignancy according to a Breast Imaging Reporting and Data System. The lesion type and breast density were determined by the consensus of two readers at each institution. The dichotomized mammographic results correlated with a final pathologic outcome and follow-up data. Receiver operating characteristic (ROC) curves, sensitivity, and specificity were compared in general and according to the lesion type and breast density. RESULTS: Of the 1038 cases, 193 (18.6%) had cancer. The areas under the ROC curve (AUC), sensitivity, and specificity of the established system were 0.815, 65.3%, and 90.2%, respectively. Those of the new system were 0.839, 68.4%, and 91.7%, respectively. There were no significant differences in the AUCs, sensitivities or the specificities in general between new and established systems (Ps = 0.194, 0.590, 0.322, respectively). We found no significant difference in these parameters according to lesion type or breast density. CONCLUSION: The new FFDM system has a comparable diagnostic performance with established systems.


Subject(s)
Adult , Aged , Female , Humans , Middle Aged , Area Under Curve , Breast Neoplasms/pathology , Mammography/methods , Prospective Studies , ROC Curve , Radiographic Image Enhancement/methods , Republic of Korea , Sensitivity and Specificity
18.
Korean Journal of Radiology ; : 171-178, 2013.
Article in English | WPRIM | ID: wpr-15372

ABSTRACT

OBJECTIVE: To report the feasibility of magnetic resonance imaging (MRI)-guided intervention for diagnosing suspicious breast lesions detectable by MRI only, using the freehand technique with a 3.0-T closed-bore MRI scanner. MATERIALS AND METHODS: Five women with 5 consecutive MRI-only breast lesions underwent MRI-guided intervention: 3 underwent MRI-guided needle localization and 2, MRI-guided vacuum-assisted biopsy. The interventions were performed in a 3.0-T closed-bore MRI system using a dedicated phased-array breast coil with the patients in the prone position; the freehand technique was used. Technical success and histopathologic outcome were analyzed. RESULTS: MRI showed that four lesions were masses (mean size, 11.5 mm; range, 7-18 mm); and 1, a nonmass-like enhancement (maximum diameter, 21 mm). The locations of the lesions with respect to the breast with index cancer were as follows: different quadrant, same breast - 3 cases; same quadrant, same breast - 1 case; and contralateral breast - 1 case. Histopathologic evaluation of the lesions treated with needle localization disclosed perilobular hemangioma, fibrocystic change, and fibroadenomatous change. The lesions treated with vacuum-assisted biopsy demonstrated a radial scar and atypical apocrine hyperplasia. Follow-up MRI after 2-7 months (mean, 4.6 months) confirmed complete lesion removal in all cases. CONCLUSION: MRI-guided intervention for breast lesions using the freehand technique with a 3.0-T closed-bore MRI scanner is feasible and accurate for diagnosing MRI-only lesions.


Subject(s)
Adult , Female , Humans , Middle Aged , Biopsy, Needle , Breast Neoplasms/pathology , Contrast Media , Diagnosis, Differential , Feasibility Studies , Gadolinium DTPA , Magnetic Resonance Imaging/instrumentation , Magnetic Resonance Imaging, Interventional/methods , Neoplasm Staging , Retrospective Studies , Vacuum
19.
Korean Journal of Radiology ; : 179-182, 2013.
Article in English | WPRIM | ID: wpr-15371

ABSTRACT

Cholesterol granuloma of the breast is a rare, benign disease. Here, we present the unique ultrasonographic findings of breast cholesterol granuloma manifesting as an intracystic mass. The findings of this case report may help expand existing knowledge regarding differential diagnosis of intracystic breast masses, which are found on ultrasonographic examination.


Subject(s)
Female , Humans , Middle Aged , Biopsy, Needle , Breast Diseases/pathology , Cholesterol , Diagnosis, Differential , Granuloma, Foreign-Body/pathology , Mammography , Ultrasonography, Mammary
20.
Journal of the Korean Society of Medical Ultrasound ; : 209-215, 2011.
Article in Korean | WPRIM | ID: wpr-725614

ABSTRACT

PURPOSE: We wanted to evaluate the interobserver variability and diagnostic performance of 3-dimensional (3D) breast ultrasound (US) as compared with that of 2-dimensional (2D) US. MATERIALS AND METHODS: We included 150 patients who received US-guided core biopsy and 3D US between June 2009 and April 2010. Three breast imaging radiologists analyzed the 2D and 3D US images using the Breast Imaging Reporting and Data System (BI-RADS) lexicon. The intra-observer agreement and inter-observer agreement were calculated. The sensitivity and specificity of 2D and 3D US were evaluated. RESULTS: The intra-observer agreement between 2D and 3D US was mostly slight or fair agreement. However, in terms of the final category, there was substantial agreement for all three radiologists. The inter-observer agreement of 3D US was similar to that of 2D US (moderate agreement for shape, orientation, circumscribed margin and boundary; fair agreement for indistinct margin, angular margin, microlobulated margin, echo pattern and final category). The sensitivity of 3D US for breast cancer was higher than that of 2D US for two radiologists (2D vs. 3D for reader 2: 55.8% vs. 61.5%, 2D vs. 3D for reader 3: 59.6% vs. 63.5%), and the specificity of 3D US was lower than that of 2D US for all the readers (2D vs. 3D for reader 1: 90.8% vs. 86.7%, 2D vs. 3D for reader 2: 90.8% vs. 87.8%, 2D vs. 3D for reader 3: 94.9% vs. 90.8%), but the difference was not significant (p > or = 0.05). CONCLUSION: The interobserver variability and diagnostic performance of 3D breast US were similar to those of 2D US.


Subject(s)
Humans , Biopsy , Breast , Breast Neoplasms , Information Systems , Observer Variation , Orientation , Sensitivity and Specificity